应用化学 ›› 2018, Vol. 35 ›› Issue (6): 722-728.DOI: 10.11944/j.issn.1000-0518.2018.06.170245

• 研究论文 • 上一篇    下一篇

超声辅助提取-固相萃取土壤中头孢菌素C的高效液相色谱法定量检测

王悦a,蔡辰b,刘惠玲b,孙丽c,李彦超d,孟昭虹a*()   

  1. a哈尔滨师范大学地理科学学院 哈尔滨 150025
    b哈尔滨工业大学城市水资源和水环境国家重点实验室 哈尔滨 150090
    c哈尔滨师范大学地理科学学院 哈尔滨 150025
    d黑龙江大学电子工程学院 哈尔滨 150080
  • 收稿日期:2017-07-12 接受日期:2017-11-09 出版日期:2018-06-01 发布日期:2018-05-28
  • 通讯作者: 孟昭虹
  • 基金资助:
    国家自然科学基金(41401589)黑龙江省自然科学基金黑龙江省高校大学专项科研资金项目(HDRCCX-2016Z10)资助

Quantitative Analysis of Cephalosporin C in Soil by High Performance Liquid Chromatography with Ultrasound-assisted Extraction and Solid-Phase Extraction

WANG Yuea,CAI Chenb,LIU Huilingb,SUN Lic,LI Yanchaod,MENG Zhaohonga*()   

  1. aCollege of Geographic Science,Harbin Normal University,Harbin 150025,China
    bState Key Laboratory of Urban Water Resources and Environment,Harbin Institute of Technology,Harbin 150090,China
    cCollege of Geographic Science,Harbin Normal University,Harbin 150025,China
    dElectronic Engineering College,Heilongjang University,Harbin 150080,China
  • Received:2017-07-12 Accepted:2017-11-09 Published:2018-06-01 Online:2018-05-28
  • Contact: MENG Zhaohong
  • Supported by:
    Supported by the National Natural Science Foundation of China(No.41401589), the Natural Science Foundation of Heilongjiang Province, Special Research Funds for the Universities of Heilongjiang Province(No.HDRCCX-2016Z10)

摘要:

建立了一种采用超声辅助提取(UAE)、强阴离子交换固相萃取(SAX-SPE)净化、高效液相色谱(HPLC)测定土壤中残留头孢菌素C(CPC)简单、快速方法。 样品以超纯水为提取剂,超声辅助提取,SPE柱子以3 mL甲醇和3 mL水活化,采用5 mL的10%甲醇水溶液作为淋洗液,2 mL的5%甲酸水溶液/甲醇溶液(体积比50:50)进行洗脱,高效液相色谱紫外检测器(HPLC-PDA)测定,检测波长λ=254 nm,柱温30 ℃ ,流动相为0.1%甲酸水溶液/甲醇溶液(体积比95:5)对土壤中不同加标浓度的CPC进行检测,方法的回收率在77.9%~98.9%,标准偏差范围为5.0%~6.3%(n=5),方法检出限(LOD)为340.4 μg/kg,定量限(LOQ)为1126.8 μg/kg。 同时采用此方法检测分析新疆某药厂附近阳性土壤样品,不同批次土壤样品结果分别为:检出(低于定量限)、1532.1 μg/kg。

关键词: 头孢菌素C, 土壤, 超声辅助提取, 固相萃取, 高效液相色谱

Abstract:

A rapid and simple method based on ultrasound-assisted extraction, solid-phase extraction followed by high performance liquid chromatography(UAE-SPE-HPLC) was proposed for the determination of cephalosporin C(CPC) in soil. The optimum pre-treatment parameters for the soil samples contaminated with CPC are as follow: ultra-pure water as extraction solvent for CPC, SPE as solid phase extraction cartridge, 5.0 mL 10% methanol as rinse solvent, 2.0 mL 5% formic acid/methanol solution(volume ratio 50:50) as eluent. The results show that when 0.1% formic acid and methanol(95:5), 30 ℃ column temperature, and 254 nm detection wavelength were applied during the isocratic elution process, HPLC assay offeres a good potential for the sensitive and selective determination of CPC. The recovery rates for seven different treatments are 77.9%~98.8%, and the precision is 5.0%~6.3%(n=5). The limit of determination(LOD) and the limit of quantification(LOQ) in soil are 340.4 μg/kg and 1126.8 μg/kg, respectively. At the same time, this method was used to detect the positive soil near the pharmaceutical factory in Xinjiang. The experimental results of different batches show detected(below LOQ), 1532.1 μg/kg and detected(below LOQ), respectively. In conclusion, UAE-SPE-HPLC is simple and rapid. Its accuracy and precision are in line with the quality control requirements. It is suitable for the detection of trace CPC in soil.

Key words: cephalosporin C, soil, ultrasound-assisted extraction, solid-phase extraction, high performance liquid chromatography