应用化学 ›› 2024, Vol. 41 ›› Issue (9): 1307-1314.DOI: 10.19894/j.issn.1000-0518.240070

• 研究论文 • 上一篇    下一篇

高精度X射线荧光光谱法在含铜污泥Cu离子测定中的应用

王莹1,2(), 武瑞平1   

  1. 1.吕梁学院化工与材料工程系,吕梁 033000
    2.吕梁学院碳基新材料及零碳负碳利用技术研究所,吕梁 033000
  • 收稿日期:2024-03-06 接受日期:2024-08-06 出版日期:2024-09-01 发布日期:2024-10-09
  • 通讯作者: 王莹
  • 基金资助:
    吕梁市大气重污染成因与治理攻关项目(LLXYHX202309-13)

Application of High-Precision X-Ray Fluorescence Spectroscopy in the Determination of Cu Ions in Copper Containing Sludge

Ying WANG1,2(), Rui-Ping WU1   

  1. 1.Department of Chemical and Material Engineering,Lyuliang University,Lvliang 033000,China
    2.Institute of New Carbon-based Materials and Zero-carbon and Negative-carbon Technology,Lyuliang University,Lvliang 033000,China
  • Received:2024-03-06 Accepted:2024-08-06 Published:2024-09-01 Online:2024-10-09
  • Contact: Ying WANG
  • About author:wyymtd@163.com
  • Supported by:
    Research Program for Key Issues in Air Pollution Control in Lvliang City(LLXYHX202309-13)

摘要:

测量含铜污泥中铜离子(Cu2+)的浓度、分布是回收Cu2+的必要步骤。因此,研究高精度X射线荧光光谱法在含铜污泥Cu2+测定中的应用十分重要。利用高精度X射线荧光光谱法对山西中条山洞沟铜矿区含铜污泥Cu2+测定进行了研究,以解决因干扰所导致测定结果偏差问题。脉冲高度分析器(PHA)范围为100~300的测定条件下,利用高精度X射线荧光光谱法测定熔融片中Cu2+浓度并修正。结果表明: 基于X射线荧光光谱图,测量出36个采样点样本中,Cu2+浓度范围从最低的8.78 mg/kg到最高的334.98 mg/kg,并通过绘制的Cu2+浓度分布特征图,得出Cu2+浓度在东南方分布最高,之后逐渐向着西北方向递减,显示出含铜污泥中Cu2+浓度的广泛变化。

关键词: 高精度X射线荧光光谱法, 含铜污泥, Cu2+测定

Abstract:

Measuring the mass concentration and distribution of copper ions in copper containing sludge is a necessary step for recovering copper ions. Therefore, it is very important to study the application of high-precision X-ray fluorescence spectroscopy in the determination of Cu ions in copper containing sludge. Due to the interference caused by the overlapping wavelength of X-rays generated by other elements and copper during the measurement process, the final Cu ion measurement results are biased. Therefore, high-precision X-ray fluorescence spectroscopy was used to study the determination of Cu ions in copper containing sludge in the Shandonggou copper mine area in Zhongtiao, Shanxi, in order to solve the problem of measurement result deviation caused by interferen PHA range of 100~300, use high-precision X-ray fluorescence spectroscopy to determine the mass concentration of Cu ions in the molten sheet and correct it. The results showed that based on X-ray fluorescence spectroscopy, the range of Cu ion mass concentration in 36 sampling point samples was measured, from the lowest 8.78 mg/kg to the highest 334.98 mg/kg. Through the drawn Cu ion mass concentration distribution characteristic map, it was found that the Cu ion mass concentration was highest in the southeast and gradually decreased towards the northwest, indicating a wide variation in Cu ion mass concentration in copper containing sludge.

Key words: High-precision X-ray fluorescence spectroscopy, Copper containing sludge, Cu ion determination

中图分类号: