摘要: 本文以W、MO-SAF-CTMAB体系为例,选取二阶和三阶导数光谱的2个不同波长下的导数值,采用简单解联立方程组的方法即可同时测定钨和钼。本文从原理和实验上证实了计算导数光度法的可行性,提出了以方程组的系数矩阵条件数来指导测量点的选择。

关键词: 导数分光光度法, 钼,

Abstract: The computation method and the differences between components are the dominated factors which affect the accuracy of an analytical determination with computation spectrophotometry.Computational-derivative spectrophotometry, based on taking advantage of the higher resolution of derivative spectrum, was proposed for the simultaneous determination of multicompo-nents. The additivity of derivative spectra and the selection of measuring points are important factors for this method. The measuring points were selected in different order derivative spectrum according to the condition number of the coefficient matrix. The concentrations of the components were calculated by solving a group of equations. The analytical applicationof the method to the W/Mo-SAF-CTMAB proves that the method is quite simple andaccurate.