Chinese Journal of Applied Chemistry ›› 1998, Vol. 0 ›› Issue (6): 25-28.
• Full Papers • Previous Articles Next Articles
Chen Ruichuan1, Lu Fang1, Li Donghui1, Zhang Changgong1, Wan Zhen2
Received:
Revised:
Published:
Online:
Abstract: An electropolymerization method of m-phenylene diamine membrane, polyphenylene diamine(PMPD) on the surface of graphite electrode is described. To identify the quality of the membrane, a rapid and sensitive method has been established based on the reaction of a horse-radish peroxidase(HRP) labeled PMPD with orthophenylene diamine. An anti-HBsAg and an antiMIgG immunoelectrodes were prepared for detecting hepatitis B surface antigen(HBsAg) and mouse immunoglobin G(MIgG). The optimum membrane preparation conditions are polymerization: 0.12 mol/L MPD solution in 1.2 mol/L H2SO4 for 20 min under 2.5 V, activation: with 3% glutiraldehyde for 4 h. The prepared HRP labeled electrode and immunoelectrodes possessed good repetition. Catibration graphs were linear for HBsAg in ranges from 0.132 g/mL and 0.120 g/mL for MIgG/mL.
Key words: immunosensor, chemically modified electrode, poly-m-phenylene diamine
Chen Ruichuan, Lu Fang, Li Donghui, Zhang Changgong, Wan Zhen. Application of Functional Electropolymerized m-Phenylene Diamine Membrane in Immunosensor Analysis[J]. Chinese Journal of Applied Chemistry, 1998, 0(6): 25-28.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: http://yyhx.ciac.jl.cn/EN/
http://yyhx.ciac.jl.cn/EN/Y1998/V0/I6/25